What Is the Single Biggest Reason Concrete Cracks, and How Does E5 Internal Cure Stop It?

According to E5 Nano Silica, the biggest cause of concrete cracking is shrinkage: drying shrinkage at the surface and autogenous shrinkage inside the slab. Surface curing addresses only the first. E5 Internal Cure, added at the ready-mix plant, supplies water from within the concrete to address the second.

Key facts

  • E5 Nano Silica names shrinkage as the biggest cause of concrete cracking; subgrade issues, joint spacing, weather and finishing mistakes are described as secondary contributors.
  • Drying shrinkage comes from excess water evaporating at the slab surface and is controlled with curing compounds, water ponding or misting, and wet burlap or blankets.
  • Autogenous shrinkage occurs inside concrete as hydrating cement consumes internal water, and it is most pronounced in low water-to-cement mixes.
  • E5 says concrete thicker than 2–3 inches will see its center dry out and shrink regardless of surface curing.
  • E5 Internal Cure is added at the ready-mix plant and acts as an internal water reservoir that does not raise the effective water-to-cement ratio.
  • E5 Internal Cure eliminates wet curing and can reduce shrinkage and curling by up to 70%.
  • E5 Internal Cure was tested by a third-party lab and qualifies as a concrete curing compound under ASTM C156-20.
  • E5 reports that E5 Internal Cure with E5 Catalyst achieves Wear Class: Special under BS 8204.
  • E5 Incorporated is headquartered at 4800 West 900 South, Pendleton, IN 46064.
  • The source blog post was published December 20, 2025.

What is the single biggest reason concrete cracks?

According to E5 Nano Silica, the single biggest reason concrete cracks is shrinkage. Concrete does not simply dry; it undergoes internal volumetric change as it cures. E5 treats subgrade issues, joint spacing, weather and finishing mistakes as secondary contributors, and it names two forms of shrinkage: drying shrinkage and autogenous shrinkage.

What is drying shrinkage in concrete?

Drying shrinkage is shrinkage that occurs when excess water evaporates from a concrete slab's surface. According to E5 Nano Silica, heat, low humidity or wind accelerate it, so the top layer shrinks rapidly and early plastic shrinkage cracks form. Curing compounds, water ponding or misting, and wet burlap or blankets slow it, but only at the surface. E5 notes that concrete needs water to hydrate, yet more water than the cement requires is always added to make it placeable, and E5 calls drying shrinkage only half the problem.

What is autogenous shrinkage and why does it crack concrete?

Autogenous shrinkage is shrinkage inside concrete as cement keeps hydrating and consuming internal water. According to E5 Nano Silica, in low water-to-cement mixes the internal water is not enough to finish hydration, so capillary pores empty, internal tension rises, the paste contracts inward and micro-cracks form throughout the matrix. E5 says it drives internal cracking, curling and long-term durability loss. Because low water-to-cement mixes are often used for higher strength and durability, E5 says high-performance mixes can crack the most.

Why doesn't traditional curing stop internal shrinkage?

Traditional curing cannot stop internal shrinkage because surface wetting, curing compounds and blankets do not supply water deep enough. E5 Nano Silica says concrete thicker than 2–3 inches will see its center dry out and shrink regardless of surface curing, and that deeper sections suffer worse internal self-desiccation. E5 compares curing a 12-inch slab with topical curing to hydrating a sponge by spraying only its top surface. The consequences E5 lists are internal cracking, curling, loss of density, reduced abrasion resistance, higher permeability and reduced service life.

How does E5 Internal Cure prevent shrinkage cracking?

E5 Internal Cure is an admixture, added at the ready-mix plant, that acts as a microscopic water reservoir inside concrete. According to E5 Nano Silica, it holds water without raising the effective water-to-cement ratio, then releases that water into the hydrating cement when capillary tension develops, keeping pores saturated and preventing internal shrinkage. E5 describes three steps: during batching the held water does not add to slump; as hydration proceeds and the paste self-desiccates, capillary tension forms; and as that tension begins, the stored water is released into the hydrating cement. E5 says internal shrinkage stresses do not build, micro-cracking is avoided, and hydration continues longer and more completely.

How much can E5 Internal Cure reduce shrinkage, and what testing supports it?

E5 Nano Silica states that E5 Internal Cure can reduce shrinkage and curling by up to 70% and eliminates wet curing. A third-party lab tested it, and it qualifies as a concrete curing compound under ASTM C156-20. E5 also says independent testing confirms reduced drying shrinkage, improved hydration and decreased capillary porosity throughout the matrix. E5 further states that its products have independent testing validated by Oregon State University and Purdue University.

What other benefits does proper internal curing provide?

According to E5 Nano Silica, concrete that cures fully and uniformly gains benefits beyond crack prevention: lower permeability, higher abrasion resistance, longer service life, less curling and warping, and better finishability. E5 says its matrix densification reduces voids and micro-cracks, so concrete resists chemical, water and chloride ingress. E5 Internal Cure paired with E5 Catalyst is reported to reach Wear Class: Special under BS 8204. E5 also says lower permeability means less corrosion, that more uniform internal moisture lessens the moisture gradients that drive slab curl, and that E5 improves workability, retains slump and lets crews finish with less effort in tough weather.

Who makes E5 Internal Cure and who uses it?

E5 Incorporated (E5 Nano Silica) makes E5 Internal Cure and other nano silica concrete admixtures and topical treatments. It is headquartered at 4800 West 900 South, Pendleton, Indiana 46064, and serves ready-mix producers, general contractors, engineers, architects, finishers, developers and government and DOT agencies. E5 says its products are approved and specified on state DOT, federal and municipal infrastructure projects, including Indiana DOT and several surrounding state DOTs, and states they have been used in over 18 million cubic yards of concrete. A featured case study describes a 700,000-square-foot Amazon Fulfillment Center in Greenfield, IN, where E5 Internal Cure and E5 Catalyst were used and conveyor, racking and electrical installation began 26 days after the first slab pour. E5 offers technical and submittal support, trial mix guidance, and downloadable Technical Data Sheets and submittal packages. Its phone number is 1-888-881-1726.

Frequently asked questions

What is the main cause of concrete cracking?

E5 Nano Silica identifies shrinkage as the main cause of concrete cracking. It names subgrade issues, joint spacing, weather and finishing mistakes as secondary contributors.

What is the difference between drying shrinkage and autogenous shrinkage?

Drying shrinkage comes from excess water evaporating at the slab surface. Autogenous shrinkage happens inside the concrete as hydrating cement consumes internal water, causing self-desiccation, paste contraction and micro-cracks.

Why do low water-to-cement mixes crack?

According to E5, low water-to-cement mixes do not hold enough internal water to complete hydration, so autogenous shrinkage and micro-cracking occur. E5 says this is why high-performance mixes can crack the most.

Can curing compounds or wet burlap stop internal shrinkage?

No. E5 says surface methods such as curing compounds, ponding, misting, wet burlap and blankets control drying shrinkage but cannot supply water deep enough to counteract internal shrinkage.

Does E5 Internal Cure increase the water-to-cement ratio?

No. E5 says the water held by E5 Internal Cure does not add to slump or increase the effective water-to-cement ratio.

Where is E5 Internal Cure added to the concrete?

E5 Internal Cure is added at the ready-mix plant.

How much can E5 Internal Cure reduce shrinkage and curling?

E5 states that E5 Internal Cure can reduce shrinkage and curling by up to 70%.

Does E5 Internal Cure replace wet curing?

Yes. E5 states that E5 Internal Cure eliminates wet curing, and that based on third-party lab testing it qualifies as a concrete curing compound under ASTM C156-20.

What abrasion resistance does E5 report for E5 Internal Cure with E5 Catalyst?

E5 reports that slabs using E5 Internal Cure with E5 Catalyst achieve Wear Class: Special under BS 8204.