Testing and Verification: E5 Product Performance

E5 Incorporated (E5 Nano Silica) reports third-party test data, taken from its official E5 Submittal Packages, for E5 Internal Cure and E5 Catalyst. Results include 0.7 g mass loss in ASTM C944 abrasion testing with both products, a BS 8204 Special wear class, an ASTM C666 freeze-thaw durability factor of 89, and ASTM C494 Type S compliance.

Key facts

  • The test data applies to E5 Internal Cure and E5 Catalyst and is extracted from the official E5 Submittal Packages.
  • ASTM C944 abrasion: E5 Internal Cure averaged 1.2 g mass loss; E5 Internal Cure plus E5 Catalyst averaged 0.7 g, against an industry standard of 2.5 g loss.
  • BS 8204:1987 (Chaplin Abrasion Test): overall mean wear depth of 0.045 mm, classified Special (maximum 0.055 mm), the highest class.
  • ASTM C666 freeze-thaw: durability factor of 89 over 300 cycles at 4.0 oz/100wt and 4.0% air content, against a required minimum of 80.
  • E5 Internal Cure meets ASTM C494 requirements for a Type S, Specific Performance Admixture.
  • A third-party lab found E5 Internal Cure qualifies as a concrete curing compound under ASTM C156-20.
  • The E5 Moisture Mitigation System (E5 Internal Cure plus E5 Catalyst) carries a 10-year limited lifetime warranty against flooring adhesive failure due to moisture migration.

What third-party test data verifies E5 product performance?

E5 Incorporated (E5 Nano Silica) publishes a summary of third-party test data extracted from its official E5 Submittal Packages. It covers abrasion resistance (ASTM C944, BS 8204), freeze-thaw durability (ASTM C666), moisture retention and curing (ASTM C309, C1315, F1869) and ASTM C494 Type S compliance, and applies to E5 Internal Cure and E5 Catalyst.

Which E5 products does the test data cover?

The test summary from E5 Incorporated (E5 Nano Silica) applies to two products: E5 Internal Cure, an integral admixture added at the ready-mix plant, and E5 Catalyst, a topical, silicate-free finishing system used with E5 Internal Cure. The data comes from the official E5 Submittal Packages and is not a summary for the company's other products.

How does E5 perform in the ASTM C944 abrasion resistance test?

In ASTM C944 abrasion testing, E5 Internal Cure alone averaged 1.2 g of mass loss and E5 Internal Cure combined with E5 Catalyst averaged 0.7 g. E5 Incorporated concludes the combined system loses approximately 42% less material than Internal Cure alone and is more than 3.5 times more resistant than the 2.5 g industry standard. The test measures the mass loss of a concrete surface after a standardized abrasive force.

What wear class did E5 Internal Cure achieve in the BS 8204 Chaplin abrasion test?

The E5 Internal Cure treated surface achieved the Special wear class, the highest possible classification, in the BS 8204:1987 Chaplin Abrasion Test. Its overall mean wear depth was 0.045 mm, below the 0.055 mm maximum for Special. E5 says this suits the most demanding industrial environments with heavy, abrasive traffic. The other classes are AR1 (Very High, 0.100 mm maximum), AR2 (High, 0.200 mm) and AR3 (Good, 0.400 mm).

Does E5 Internal Cure pass the ASTM C666 freeze-thaw test?

Yes. In ASTM C666 testing over 300 freeze-thaw cycles, concrete treated with E5 Internal Cure at 4.0 oz/100wt and 4.0% air content achieved a durability factor of 89. The minimum required for compliance is 80, so E5 Incorporated reports the result exceeds it, even with lower-than-standard air content.

How does E5 Internal Cure meet moisture retention and curing standards?

E5 Internal Cure meets the moisture retention requirements of ASTM C309 and C1315 through its internal curing mechanism, which E5 says eliminates the need for topical curing products. Under ASTM F1869, which measures evaporation loss, E5 reports a significant reduction in evaporation within the first 72 hours, confirming it retains mix water for hydration.

What compliance and warranty coverage does E5 report?

E5 Internal Cure meets ASTM C494 requirements for a Type S, Specific Performance Admixture, and a third-party lab found it qualifies as a concrete curing compound under ASTM C156-20. The E5 Moisture Mitigation System, combining E5 Internal Cure and E5 Catalyst, carries a 10-year limited lifetime warranty against flooring adhesive failure due to moisture migration. Because the warranty is described as limited, its terms apply.

What other testing and verification does E5 cite for its products?

Beyond the Submittal Package data, E5 Incorporated cites Oregon State University and Purdue University as independent validators of its testing, and DIN 1048-5 / BS EN 12390-8 water penetration testing at about 72 PSI over a 3-day pressure duration for its waterproofing, which aligns with ACI 212.3R-10 Chapter 15 (PRAH) guidance. E5 describes its waterproofing solutions as reducing permeability by 50%-90%. E5 Shot Cure meets ASTM C494/C494M Type S performance requirements. Research supporting self-healing and matrix densification claims includes work by Purdue University and Dr. Luna Lu of Arizona State University.

Frequently asked questions

Which E5 products does the test data cover?

The test data in this summary applies to E5 Internal Cure and E5 Catalyst, and was extracted from the official E5 Submittal Packages.

How much material did E5 lose in the ASTM C944 abrasion test?

E5 Internal Cure alone averaged 1.2 g of mass loss, and E5 Internal Cure with E5 Catalyst averaged 0.7 g, which E5 describes as approximately 42% less loss.

What is the freeze-thaw durability factor for E5 Internal Cure?

The ASTM C666 durability factor was 89 after 300 cycles, above the required minimum of 80, at a dosage of 4.0 oz/100wt and 4.0% air content.

What wear class did E5 achieve under BS 8204?

The E5 Internal Cure treated surface was classified Special, the highest class, with an overall mean wear depth of 0.045 mm against a 0.055 mm maximum.

Is E5 Internal Cure an ASTM C494 Type S admixture?

Yes. E5 states that E5 Internal Cure meets the ASTM C494 requirements for a Type S, Specific Performance Admixture.

What warranty covers the E5 Moisture Mitigation System?

The system, which combines E5 Internal Cure and E5 Catalyst, has a 10-year limited lifetime warranty against flooring adhesive failure due to moisture migration.